Carrier Access Access Bank II SNMP User Manual

Page 155

Advertising
background image

14-10

9/24/01

2. Type help at the prompt to list all of the commands and options, as shown below.

Commands ............. Command LineInterface Help. Forimmediate

context sensitive help, type ? at any

time.

For full command help, type “help” after

any partial command.

\

................. Enter \ to go to the top command level

aco

................. Display/Set Alarm Cutoff

off ................ Disable alarm

on ................. Enable

alarm

alarms ............... Display/Set current alarms

all on|off ......... Set all alarms

sys ................ Display/Set system alarms

power

on|off .. Hard reset or power on detected

brownout on|off .. Brown out detected

reset

on|off .. Soft reset detected

vn ................. Display/Set alarms for V.35 #n

rts

on|off .. Loss of V.35 RTS

llb

on|off .. Local Loop Back detected

v54

on|off .. Remote V.54 Loop Back detected

dn ................. Display/Set alarms for ds1 #n

carrier

on|off .. Loss of carrier detected

csuloop

on|off .. CSU loop code received

unframed on|off .. Unframed, all 1’s received

sync

on|off .. Loss of sync

yellow

on|off .. Yellow alarm received

bpv

on|off .. BPVs exceed 1544 in 15 min period

ses

on|off .. SES exceed 10 in 15 min period

unavail

on|off .. Unavailable seconds in 15 min period

fdlline

on|off .. FDL line loop request received

fdlpay

on|off .. FDL payload loop request received

aps

................. Display/Set Automatic Protection Switching

off ................ Disable APS mode

primary dn ......... Set either d1 or d2 as primary span

threshold n ........ Set BPV switch threshold to 10^-n, 4<=n<=6

boot ................. (Re)Boot the system... all connections

will be dropped during initialization

clk

................. Display/Set T1 Clock

primary ............ Set T1 Primary Clock Source

t11 .............. Set Clock Source to T1 #1

t12 .............. Set Clock Source to T1 #2

internal ......... Set Clock Source to internal

secondary .......... Set T1 Secondary Clock Source

Advertising