Table 9-3, Table 9-4, Brfxs/dpo back plate switches switch function – Carrier Access Access Bank II SNMP User Manual

Page 94: Brfxs/dpo back plate leds led state condition, Figure 9-4: brfxs/dpo back plate controls and leds

Advertising
background image

BRFXS/DPO Configuration Settings

9/24/01

9-21

Figure 9-4: BRFXS/DPO Back Plate Controls and LEDs

Table 9-3

BRFXS/DPO Back Plate Switches

Switch

Function

Channel Test
(12 per card)

Applies reverse battery to
CPE loop and forces A/B bits
sent toward network to 1/1

TP Busy/Idle
(One per card)

Selects reverse (busy) or
forward (idle) battery on tip-
ground relays during trunk
processing

Table 9-4

BRFXS/DPO Back Plate LEDs

LED State

Condition

OFF

Idle state

(forward battery)

Green

Incoming call

(reverse battery)

Yellow

Call in Progress

(reverse battery)

Red

Outgoing line seizure

(forward battery)

All LEDs Yellow

AB 1 in trunk processsing

All LEDs Flash Red

Unsupported signaling option
selected

Channel 22

Channel 21

Channel 20

Channel 19

Channel 18

Channel 17

Channel 16

Channel 15

Channel 14

Channel 13

Test 20

Test 19

Test 18

Test 17

Test 16

Test 15

Test 14

Test 13

TP Busy/Idle

Option C

Option B

Option A

Test 12

Test 11

Test 10

Test 9

Channel 12

Channel 11

Channel 10

Channel 9

Channel 8

Channel 7

Channel 6

Channel 5

Channel 4

Channel 3

Channel 2

Channel 1

Test 8

Test 7

Test 6

Test 5

Test 4

Test 3

Test 2

Test 1

TP Busy/Idle

Option C

Option B

Option A

Test 24

Test 23

Test 22

Test 21

Channel 24

Channel 23

Channel Test
Switches &
Indicators
Channels 13-16

TP Busy/Idle Switch
Channels 13-24

Channel Test
Switches &
Indicators
Channels 1-4

TP Busy/Idle Switch
Channels 1-12

Channel Test
Switches &
Indicators
Channels 5-8

Channel Test
Switches &
Indicators
Channels 9-12

Channel Test
Switches &
Indicators
Channels 17-20

Channel Test
Switches &
Indicators
Channels 21-24

Advertising