Ee figure 8-2), Figure 8-2) – Carrier Access Access Bank II SNMP User Manual

Page 78

Advertising
background image

Setting the FXS Transmit and Receive Levels

9/24/01

8-5

Figure 8-2: Accessing the FXS-ID Cards

Table 8-2: FXS Signaling Summary

Option
Number

Switch
A

Switch
B

Switch
C

Signaling
Option

0

OFF

OFF

OFF

Normal FXS A&B signaling for loop-
start or ground-start; automatic selection
based on carrier signal. FXS-ID card
default.

1

ON

OFF

OFF

E&M wink-start-to-loop-start conversion
with ringback to T1 line and calling party
disconnect (Megacom, Notes 1 and 2).

2

OFF

ON

OFF

E&M wink-start-to-ground-start
conversion with ringback to T1 line
(Megacom, Note 1).

3

ON

ON

OFF

E&M immediate-start-to-loop-start
conversion with ringback to T1 line and
calling party disconnect (Megacom,
Notes 1 and 2). Also known as Private
Line Automatic Ringdown (D3 PLAR).

Advertising