15 - technical data – Slant/Fin VSL-160C Part C User Manual

Page 26

Advertising
background image

98

MODEL

VSL-160-B; VSL-160-C;

Country of destination

USA and Canada

Type of boiler

Direct Vent and room combustion air

Category of discharge chimney

IV

CSA certifi cate N°

2045300 (114696)

Maximum Heat input

Btu/hr

160,000

Minimum heat input

Btu/hr

30,000

Effi ciency at maximum heat input (160°F/140°F)

%

93

Maximum Heat output (160°F/140°F)

Btu/hr

148,800

Effi ciency at minimum heat input (122°F/86°F)

%

97

Minimum heat output (122°F/86°F)

Btu/hr

29,100

Certifi ed AFUE rate

%

91.5

Gas fl ow rate

Natural gas

ft3/hr

156

LP Gas

gal/hr

1.75

Gas supply pressure

Natural gas

In.W.C.

7

LP Gas

In.W.C.

11

Minimum gas supply pressure

Natural gas

In.W.C.

3

LP Gas

In.W.C.

3

Maximum gas supply pressure

Natural gas

In.W.C.

13

LP Gas

In.W.C.

13

Combustion air pressure with min. length

Natural gas

In.W.C.

2.5 to 3.1

LP Gas

In.W.C.

2.1 to 2.7

Combustion air pressure with max. length

Natural gas

In.W.C.

2.1 to 2.7

LP Gas

In.W.C.

1.8 to 2.4

Instantaneous d.h.w production [rise 75°F (42°C)]

gal/min

4.32

Maximum heating temperature

°F

189

Minimum heating temperature

°F

68

Maximum heating pressure

PSI

30

Minimum heating pressure

PSI

8

Maximum pressure of domestic hot water circuit

PSI

150

Minimum pressure of domestic hot water circuit

PSI

1

Capacity of expansion tank (160-C model only)

gal

2.64

Supply voltage

120Vac - 60Hz

Absorbed electric power

W

170

Flue gas pipes diameter (split)

“ (mm)

3.15” (80)

Max. length fl ue gas pipes (split)

ft

300

Flue gas pipes diameter (coaxial)

“ (mm)

2.36/3.94 (60/100)

Max. length fl ue gas pipes (coaxial)

ft

70

Equivalent length of one elbow

ft

45° elbow = 3ft, 90° elbow = 5ft

CO (Carbon monoxide) with natural gas

ppm

<150

CO (Carbon monoxide) with LP gas

ppm

<250

NOx (0% O2 with natural gas)

ppm

<30

CO2 (Carbon dioxide) for Natural gas at high fi re

%

9.1 to 9.3

CO2 (Carbon dioxide) for Natural gas at low fi re

%

8.4 to 9

CO2 (Carbon dioxide) for LP gas at high fi re

%

9.3 to 9.7

CO2 (Carbon dioxide) for LP gas at low fi re

%

9.2 to 9.8

O2 (Oxygen) for Natural gas at high fi re

%

4.4 to 4.6

O2 (Oxygen) for Natural gas at low fi re

%

5.1 to 5.7

O2 (Oxygen) for LP gas at high fi re

%

5.7 to 5.9

O2 (Oxygen) for LP gas at low fi re

%

6.1 to 6.7

Ionisation current

71 to 90

Maximum fl ue gas temperature

°F

210

Flue gas mass-fl ow

lb/hr

160

Head pressure available for fl ue vent/air intake line

In.W.C.

3.6

Maximum condensation fl ow rate

gal/hr

1.32

Average acidity of condensation

PH

4

Boiler weight (empty of water) (160-C model)

lb

125

Boiler weight (empty of water) (160-B model)

lb

93

15 - TECHNICAL DATA