DHWG Domestic Hot Water Generator

DOMESTIC HOT WATER GENERATOR

DHWG

Figure 3. Water piping from boiler to DHWG system (Bobcat B-120A shown)

Water Piping:

1. Make all piping connections to and from the DHWG system

as shown in Figure 3.

2. Isolation valves and unions are recommended on all

piping connections to the DHWG system, to facilitate any

possible service needs. Use full port valves to insure

proper water flow through the system.

3. The piping to and from the boiler should be kept as short

as possible, with a minimum number of restrictions, such

as elbows. The diameter of the piping must not be

reduced from the DHWG system’s provided connection size.

4. The piping for the domestic water in and out should be

adequately sized for the desired flow rates at each

fixture. The distance to each fixture should be considered,

for the response rate of adequate hot water to each.

5. Refer to the boiler manual “Water Piping” section, for

proper installation of the space heating system and all

other piping.

CAUTION: A tempering valve is recommended to be installed
on the hot water outlet to all fixtures where direct user contact

can be made with the water supplied by the DHWG system to

prevent any possible scalding conditions. See Figure 3 for the

appropriate installation method of this device (not supplied with

the DHWG system).