TRDV SERIES

CONNECTIONS TO THE OUTSIDE TERMINAL

Use Figure 8 and Figure 9 to complete the following steps.

1. Slide the inner section over the vent pipe.

2. Connect the inner adapter to the vent pipe as per joint

assembly.

3. Apply a bead of sealant around the terminal flue collar.

4. Slide the appliance adapter over the flue collar

5. Tighten the gear clamp of the terminal adapter around the flue

collar.

6. Seal the seam in the adapter with sealant.

7. Slide the inner section over the outer section and secure by

tightening the gear clamp.

8. Air intake piping is field supplied and must be installed

according to local code requirements. Galvanized flue pipe or
Flex L air intake piping can be used. For optional Flex L air
intake piping, stretch the air intake flex to desired length and
slide over the air intake collar. Seal the connection with the alu-
minum tape and secure using air intake clamp. Beaded end of
(Figure 7) the air intake clamp should go first over the air intake
collar.

9. All seams and gaps should be sealed. For the Flex L piping,

seal the gap between the vent pipe and the inner section with
silicone sealant.

FIGURE 8: Vent terminal to flue pipe connection

FIGURE 9: Connection to fresh air intake

FLEX- L