E. EXHAUST REQUIREMENTS

Exhaust duct work should be designed and installed by a qualified technician. Improperly sized duct work
will create excessive back pressure which results in slow drying, increased use of energy, overheating of the
dryer, and shutdown of the burner by the airflow (sail) switch, burner hi-limit, or lint chamber hi-heat
protector thermostat. Refer to the following illustrations for details.

CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCT WORK CAN

CREATE A POTENTIAL FIRE HAZARD.

MULTIPLE DRYER VENTING

WITH AN "A" DIAMETER EXHAUST CONNECTIONS AT COMMON DUCT

N0, OF DRYERS

8

7

6

5

4

3

2

1

MINIMUM CROSS
SECTION AREA (SO,IN,)

B

D

F

H

j

L

N

P

MINIMUM ROUND
DUCT DIAMETER (IN,)

C

E

G

1

K

M

0

0

VERTICAL

HORIZONTAL

WALL

2 X DIA CLEARANCE

2 X D CLEARANCE

ROOF

TUMBLER EXHAUST MUST ENTER MAIN
EXHAUST DUCT AT A Z5° ANGLE,

1^ SEE NOTE B

FOR MINIMUM DISTANCES
BETWEEN DUCTS

IMPORTANT: NO MORE THAN 8 DRYERS CAN

BE CONNECTED TO ONE COMMON DUCT (VENT),

MAN3725

FORMULAS TO CALCULATE DUCTING CROSS SECTIONAL AREA

CROSS SECTIONAL AREA OF A ROUND DUCT = ,785 x DIA^

CROSS SECTIONAL AREA OF A RECTANGULAR DUCT - WIDTH x HEIGHT

HEIGHT

—IWIDTHh“

NOTE A: OPENING MUST BE TWO (2) INCHES LARGER THAN DUCT (ALL THE WAY AROUND), THE DUCT

MUST BE CENTERED WITHIN THIS OPENING,

NOTE B, 75 lbs-38 VA­

NOTE B, 50 lbs,-38 1/4", 30 lbs-31 3/8"

75 lbs.
Dryer Exhaust Duct Size: 8"
Dryer Air Flow: 1,200 cfm

A

B

c

D

E

F

G

H

1

J

K

L

M

N

O

P

Q

8"

530

26

455

24

455

24

380

22

315

20

255

18

200

16

115

12

50 lbs.

30 lbs.

Dryer Exhaust Duct Size: 8"
Dryer Air Flow: 600 cfm

A

B

c

D

E

F

G

H

1

J

K

L

M

N

0

P

Q

8”

380

22

315

20

315

20

255

18

200

16

155

14

115

12

80

10