Natural gas l.p. gas, 4 inches w.c, 11 inches w.c – Maytag MC2 User Manual

Page 19

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

During this purging period, check to be sure ALL gas shut-off valves are open. If the dryer still fails
to heat, refer to the troubleshooting guide.

5. Make a complete operational check of ALL the operating controls to assure that the timing is correct,

temperature selection switches are functioning, etc.

6. Make a complete operational check of ALL safety-related circuits - door switch(es), hi-limit

thermostat, sail switch, cycling thermostats, etc.

7. A gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water

column pressure is correct and consistent.

NOTE: Water column pressure requirements as measured at the gas valve pressure tap are:

Natural Gas

L.P. Gas

4 inches W.C.

11 inches W.C.

This will give a 3-1/2 inch water column manifold pressure for natural gas and a ten (10) inch for L.P.

8. If program changes are required, refer to your User's Manual.

9. The dryer should be operated through one complete cycle to assure that no further adjustments are

necessary and that ALL components are functioning properly.

IMPORTANT: The dryer tumbler (basket/drum) is treated with a protective coating. We suggest

tumbling old clothes or material in the basket using a mild detergent to remove
coating.

10. On 3-phase models, check the electric service phase sequence. While the dryer is operating, check to

see if the tumbler (basket/drum) is rotating in the clockwise direction (when viewed from the front). If
so, the phasing is correct. If the tumbler rotates counterclockwise, the phasing is incorrect. Correct by

reversing two (2) leads at connections LI, L2, or L3 of power supply to the dryer.