For added personal safety, when possible, it is suggested that a separate ground wire
(no. 18 minimum) be connected from the ground connection of the dryer to a grounded cold water
pipe. DO NOT ground to a ^as pine.

I NOTE: For 100 lb. model, a no. 12 minimum separate ground wire should be used.

The grounded cold water pipe must have metal to metal connection all the way to electrical ground.
If there are any non-metallic interruptions, such as, a meter, pump, plastic, rubber or other
insulating connectors, they must be jumped with no. 4 copper wire and securely clamped to bare
metal at both ends.

IMPORTANT: For personal safety and proper operation, the dryer must be grounded.

4. Electrical Connections

A wiring diagram is located on the back side of the control (service) door for connection data.

Single Phase Hookup

On the single-phase dryers, the electrical input connection is made to the three connection leads (LI,
L2 or N and ground) extending out of the junction box located at the upper left rear of the dryer.

Single-Phase Electrical Connection Leads

Black

White

Oreen

+

-

Psitive

Neutral

Ground

(LI)

(L2)

(CMD)

plioloOOhS