OPERATION

WHAT TO DO IF ..?

6. What to do if

6.1 ...the water supply is interrupted?

A

Risk of damage

) \ After an interruption to the water supply, take the

following steps prior to returning the appliance into

use.

» Remove fuses or trip the appropriate MCBs.

8 Open a draw-off valve downstream of the appliance long enough

to vent all air from the appliance and its upstream cold water

supply line.

»Replace the Fuses upstream or reset the relevant MCBs.

.faults occur on the appliance?

Remedy

»Check the fuse/MCB in

yo.ir fuse hox/distrihij*
lion panel.___________

»Clean »nd/or descale the

pcrlclor or Ihc shower
head.

»Contact your he&ting

contractor.___________

The appliance restarts
automatically after one

minute.

6.2

Fault

Cause

The appliance will not There is no voltage.
start in spite of a fully
open DHW valve. ____________________

Cold v/ater flows
hrieflywhile hotwater
is being drawn.

Starting volume is not
achieved. The perlitlor in
the tap or shower head Is
scaled up or dirty._____

The heating system is
faulty.______________

The air sensor detects air

in the water and briefly

switches the heater off.

If you cannot remedy the fault, contact your heating contractor.

For better and faster help, provide him with the serial number

from the type plate (no. 000000-0000-000000):

22 IDHB-E ... SLi eLectronic