INSTALLATION
INSTALLATION

B.5.5 Offset instalfation pipe assembly

Part number 220290, ccmprismg: Universal mcunting Frame {For

technical description see part number 220291) and pipe bendsfor

the vertical offset of the appliance against the water connection

by 90 mm downwards.

Pipe assembly, replacement of a gas fired water heater

Part number 220510, comprising: Universal mounting frame (for

technical description see part number 220291) and pipe bends For

installation with existing gas Fired water heater connections (cold

water connection on the left: DHW connection on the right).

B.5.7 DHB replacement pipe assembly

Part number 159B76, comprising: 2 x water plug-in couplings.

These allow the appliance to be connected to the available water

plug-in connections of a DHB.

B.S.B Load shedding relay LR 1*A

Part number 0017B6. The load shedding relay enables operation

with,

for

example,

electric

storage

heaters.

The

instantaneous

water heater is operated via the load shedding relay prior to any

other appliance.

9. Installation

9.1 Insiallaiion information

9.1.1

Flow pressure

If the flow rate required for the appliance to switch on is net

achieved even with the tap fully open, remove the flow limiter.

Replace it with the plastic profile wnsher supplied. If required the ^

pressure in the water inslalintion can also be raised.

A

Thermostatic valves.

For the thermostatic valve to function correctly, the

flow limiter for this valve must not be replaced with

the plastic profile washer.

19

1

Flow limiter

2

Plastic profile washer

9.1.2

Flexible water connection lines

If the appliance is connected with flexible water connection lines,

ensure that the bayonet fittings of the pipe bends do not become

twisted inside the appliance.

9.1.3

Appliance with changeover connected load

The appliance DHB-E lB/2l/24SLiissetto2l kW when delivered.

If the appliance is installed with a different output, take the

following steps:

»Re-plug the coding card according to the selected output: for

selectable

output

and

fuse

protection

of

the

appliance

see

"Specificaticn“.

»Mark the selected output on the type plate using a permanent

marker.

»Install the flew limiter with a rating corresponding to that of

the appliance. The colour of the flow limiter is given in the table

"Specification".