INSTALLATION
INSTALLATION

9.4.4 Pitting powfir table

Installing the power cable

160________

A

''k

30.

--------- -

1

» Prepare the power cable.

»Use the plastic cap as an installation aid.

9.4.5 Inserting the twin nipples

9.4.6 Preparing the water connection

»Secure the lee and cross-piece to the twin nipples with flat

packing.

»Thoroughly flush the cold water supply line.

• I Three-way shut-off valve

11 Never use the three-way shut-off valve to reduce the

flow rate: it is only designed to shut off a circuit.

1

Tee

2

Cross-piece

9.4.7 Fitting the sieve

» Fit the sieve provided in the cold water inlet of the appliance.

Vl sieve

1-1 The sieve must always be fitted for the function of the

appliance to be guaranteed. If an appliance is being

replaced during installation, ensure (hat a sieve is

available.

Fitting the sieve

t/i

_i

19

9.4.8 Installing (he DMB flow limiter

»Position the Flew limiter provided in the cold water inlet of the

appliance.

A second flow limiter is provided with the DHB-E 18/21/24 SLi.

Install the Flew limiter with an output corresponding to that of

the appliance. The colour of the flow limiter is given in the table

"Specification".

9.4.9 Mounting the appliance

The cable grommet pointing towards the wall may hinder the

mounting of the appliance close to the wall. To prevent such

problems, it is advisable to briefly press the cable grommet

www.stiebeL-eltron.com