INSTALLATION
INSTALLATION

9.S Installation versions

9.5.1

Power supply from above for unfinished vi/alls

Thefollowing diagram shows the dimensions for the power supply

from above.

»Open out the cable grommet to match the cross-section of the

power cable.

»Push down and remove the locking hookthat secures the mains

terminal.

»Move the mains terminal in the appliance from the bottom to

the top and click into place.

Power supply from above

9.5.2

Power supply for finished walls

The appliance can also be connected if the power supply has been

routed over finished walls. This applies to the connection from

below and above. Take the fallowing steps:

»Cut

or

break

knock-outs

in

the

back

panel

and

appliance

cap. Possible knock-out paints can be seen in the diagram

"Dimensions for power supply".

•~| Changing the type of protection

1-1 If the appliance has been connected with a power

supply on finished walls, the type of protection on the

type plate must be changed from IP 25 to IP 24. Use a

permanent marker for that.

»Cress out *IP 25" and mark the box "IP 24".

9.5.3

Power supply for large cross*$ections

Removing and installing the cable grommet

CO
_l

19

If cables with a large cross-section are used, the cable grommet

enn be fitted after the appliance has been installed. Take the

following steps:

»Before installing the appliance, use a screwdriver to push the

cable grommet out.

»Push the appliance over the stud of the mounting bracket, sc

that it breaks through the soft seal.

»Push the fixing toggle onto the stud of the mounting bracket that

penetrates the back panel.

»Press the back panel h'rmlyinto place and lockthe fixing toggle

by turning it through 90^

» Push the cable gremmet over the power cable. For this, use the

installation aid. For a power cable of 10 or 16 mm^, the hole in

the cable grommet must be enlarged. Click the cable grommet

into place in the back panel.

9.5.4

Connecting a load shedding relay

Install the load shedding relay in conjunction with other electric

appliances, e.g. electric storage heaters. The relay responds when

the instantaneous water heater starts. The load shedding relay is

available from Stiebel Eltron as a special accessory.

www.stiebeL-eltron.com