Set port vtag (se po vt), Set port group (se po gr), Add user (ad us) – Datacom Systems VS-1200 User Manual

Page 25: Edit user (ed us)

Advertising
background image

Initial Configuration

25

© 2009 Datacom Systems Inc

4.1.4.11 SET PORT VTAG (SE PO VT)

This command is used to change the capability of a port to either pass VLAN Tags or strip them
from a frame and recalculate the CRC of the frame as shown:

SE PO VT (Comma separated list of port numbers, port names, or group names) ON/OFF

Example: # SE PO VT 1,4,6,7 ON
#

4.1.4.12 SET PORT GROUP (SE PO GR)

This command is used to create a port list under a common name for ease of use. When displayed,
the common name is all caps, regardless of case entry. As part of this command, there is a command
separator (CONTAINS) or, if the OFF parameter (delete the group) is used, the CONTAINS is
not used. A maximum of 10 groups is allowed.

Groups, as designated by the administrator (Superuser,) belong to the same logical group.
Specifically, groups can be configured as if they were a single logical port, enabling a high degree of
control during both the initial setup and all subsequent moves or changes as shown:

SET PORT GROUP (SE PO GR) group name [OFF] or [CONTAINS] port list

Example: # SE PO GR DatacomPorts CONTAINS 4,5,6
# SE PO GR DatacomPorts OFF
#

4.1.4.13 ADD USER (AD US)

This command is used to add users to the configurable product as shown:

ADD USER (AD US)

Example: # AD US
Enter New Username: newuser
Confirm Password: ****
User newuser has been saved
#

4.1.4.14 EDIT USER (ED US)

This command edits Usernames/Passwords as shown:

EDIT USER (ED US) user name

Example: # ED US newuser
Enter New Username: edituser
Enter Password: ****
Confirm Password: ****

User edituser has been saved

#