Datacom Systems VS-1200 User Manual

Page 38

Advertising
background image

VS-1200 Data Acccess Switch

38

© 2009 Datacom Systems Inc

Then enter Superuser mode, at the user prompt >, enter

SU, Enter key, and enter the Password

(default: password) and

Enter key. Default prompt is the # symbol.

In Superuser mode use the following syntax for the different connections. This syntax sets the input/
output for Any-to-Any ports as well as the input/output for Tap ports.

The VS-1200 Series factory default for all Any-to-Any ports is off.

Ensure there are no previous settings present, go through Ports 1-10 and set them to OFF as
shown:

# SET PORT MONITOR 1 OFF
# SET PORT MONITOR 2 OFF
# SET PORT MONITOR 3 OFF
# SET PORT MONITOR 4 OFF
# SET PORT MONITOR 5 OFF
# SET PORT MONITOR 6 OFF
# SET PORT MONITOR 7 OFF
# SET PORT MONITOR 8 OFF
# SET PORT MONITOR 9 OFF
# SET PORT MONITOR 10 OFF

Now you can begin setting the Tap and Monitor ports as to which port inputs the data and which
ports aggregate and/or output the data.

Port 1 is set as output for Ports 7 and 9’s input which is set with this syntax:

# SET PORT MONITOR 1 FROM 7,9

Port 2 is set as output for Ports 8 and 9’s input which is set with this syntax:

# SET PORT MONITOR 2 FROM 8,9

Advertising