Figure 4-8, Delayed trigger – ADLINK USB-1903 User Manual

Page 59

Advertising
background image

Operation

45

USB-1900 Series

USB-1900 Series starts to acquire data. The total acquired data
length = NumChan_counter * PSC_counter.

Figure 4-8: Delayed Trigger

4.4.3

Post-Trigger or Delayed-Trigger Acquisition with

Retriggering

Post-trigger or Delayed-Trigger acquisition with re-trigger function
is indicated where you want to collect data after several trigger
events. The number of scans after each trigger is specified in
PSC_counter, and Retrig_no can be programmed to specify the
re-trigger numbers. An example is shown, in which two scans of
data are acquired after the first trigger signal, after which the
USB-1900 Series waits for the next re-trigger signal (re-trigger sig-

WARNING:

When the Delay_counter clock source is set to timebase, the
maximum delay time = 2

32

/80M s = 18.626ms

(NumChan _Counter=4, PSC_Counter=3)

Acquisition_in_progress

Scan_start

AD_conversion

Acquired & Stored Data

(3 scans)

Operation start

Trigger

Delay until
Delay_Counter
reaches 0