4 mode 4: single-gated pulse generation, 5 mode 5: single-triggered pulse, Mode 4: single-gated pulse generation – ADLINK USB-1903 User Manual

Page 74: Mode 5: single-triggered pulse, Figure 4-20, Mode 3-single pulse-width measurement, Figure 4-21, Mode 4-single-gated pulse

Advertising
background image

60

Operation

Figure 4-20: Mode 3-Single Pulse-Width Measurement

4.8.4

Mode 4: Single-Gated Pulse Generation

This mode generates a single pulse with programmable delay and
programmable pulse-width following software start. The two pro-
grammable parameters can be specified in terms of periods of the
GPTC_CLK input by the software application. GPTC_GATE
enables/disables calculation. When GPTC_GATE is inactive, the
counter halts the current count value. Generation of a single pulse
with a pulse delay of two and a pulse-width of four is shown.

Figure 4-21: Mode 4-Single-Gated Pulse

4.8.5

Mode 5: Single-Triggered Pulse

This mode generates a single pulse with programmable delay and
programmable pulse-width following an active GPTC_GATE edge.
These programmable parameters can be specified in terms of

0

0

1

2

3

4

5

5

5

Gate

CLK

Count value

Software start

2

2

1

0

3

2

2

1

0

Gate

CLK

Count value

OUT

Software start