Figure 4-16, Post-trigger or delayed-trigger with retriggering – ADLINK USB-1903 User Manual

Page 68

Advertising
background image

54

Operation

After two trigger signals, as specified in Trig_Counter, no more
trigger signals will be accepted unless a trigger reset command
is executed. For more information on the Iterative Waveform
Generation in this example, please see the next section.

Figure 4-16:

Post-Trigger or Delayed-Trigger with Retriggering

Iterative Waveform Generation

You can set the IC_counter to generate iterative waveforms
regardless of the trigger mode used. The IC_counter stores the
iteration number, as shown in the following two examples.

WARNING:

Start trigger signals asserted during waveform generation will
be ignored.

WARNING:

When the IC_counter is disabled, waveform generation will
continue until the counter is reset.

UC_Counter = 3

3 update counts and 2 iterations

UC_count = 3, IC_count = 2, Trig_count = 3, DLY1_count disabled, DLY2_count

disabled

Trigger

DAWR

WF_in_Prog

Wave

Ignored

Single waveform

Advertising