Irq), 6 irq level setting – ADLINK ACL-6126 User Manual

Page 15

Advertising
background image

Installation 9

I/O port

address(hex)

fixed

A9

1

A8

2

A7

3

A6

4

A5

5

A4

200-20F

OFF

(1)

ON

(0)

ON

(0)

ON

(0)

ON

(0)

ON

(0)

210-21F

OFF

(1)

ON

(0)

ON

(0)

ON

(0)

ON

(0)

OFF

(1)

:

(*) 2C0-2CF

OFF

(1)

ON

(0)

OFF

(1)

OFF

(1)

ON

(0)

ON

(0)

:

300-30F

OFF

(1)

OFF

(1)

ON

(0)

ON

(0)

ON

(0)

ON

(0)

:

3F0-3FF

OFF

(1)

OFF

(1)

OFF

(1)

OFF

(1)

OFF

(1)

OFF

(1)

(*) : default setting ON : 0
X : don't care OFF : 1
Note: A4, ..., A9 correspond to PC bus address lines.

2.6 IRQ Level Setting

A hardware interrupt can be triggered by the external Interrupt signal
which is from pin 17 of CN3 connector. Its corresponding interrupt IRQ
levels can be selected by jumper JP7. The jumper setting is specified
as below:

Note : Be aware that there is no other add-on cards sharing the same

interrupt level in the system.

(IRQ)

10 11 12 15 X

3 5 6 7 9

Interrupt Default Setting = IRQ15

Note:External trigger source is from Pin-17 of CN3

Figure 2.3 IRQ Setting

Advertising