2.7 D/A Output Configuration

The ACL-6126‘s output channels can be configured as different analog
output styles, and they are dependent on D/A converter's reference
voltage source
and output mode( Bipolar or Unipolar). The reference
voltage can be generated internally or by external reference voltage
from the Reference Voltage Input ( REF.IN) of connector P1. Each
output channel and its corresponding jumpers are listed as follows.

Channel NO.

Corresponding Jumper

CH0 JP1-3
CH1 JP2-3
CH2 JP3-3
CH3 JP4-3
CH4 JP5-3
CH5 JP6-3

The jumper settings for each output channel are illustrated as below
Figure 2.4 . The internal -5V is set as default reference voltage.

Reference

Voltage

Source

External Ref.

-10V Ref.

-5V Ref.

( default )

Jumper

Setting

EXT

-5V

-10V

EXT

-5V

-10V

EXT

-5V

-10V

Figure 2.4 Reference Voltage Source