Un bi jp1-1 jp1-2, Un bi – ADLINK ACL-6126 User Manual

Page 17

Advertising
background image

Installation 11

Besides, each output channel can be set as Bipolar or Unipolar output.
Each output channel and its corresponding jumpers for mode setup are
listed as follows.

Channel NO.

Corresponding Jumper

for output mode

CH0 JP1-1,

JP1-2

CH1 JP2-1,

JP2-2

CH2 JP3-1,

JP3-2

CH3 JP4-1,

JP4-2

CH4 JP5-1,

JP5-2

CH5 JP6-1,

JP6-2


The jumper settings for output channel CH0 are illustrated as below
Figure 2.5. The Unipolar mode is default setting.

Output Mode

Unipolar

( default )

Bipolar

CH0

UN

BI

JP1-1 JP1-2

UN

BI

JP1-1 JP1-2

Figure 2.5 Output Mode Setting for CH0


The different output ranges of output CH0 are shown as the following
table. The settings for reminder channels(CH1 ~ CH5) should follow the
same rules as CH0.

Output Range

JP1-3

JP1-1 & JP1-2

0 to +5V

Unipolar

(Default)

EXT

-10V

-5V

UN

BI