Installation 15

2.9 Signal

Connection

A correct signal connection is quite important to send data accurately.
In this section, a helpful information is present for how to make proper
signal connection when the ACL-6126 is used.
Voltage Output Connection

Amp

Load

V.OUT

A.GND

ACL-6126 Side

External Side

load

R


Current Sink Connection

Amp

.

I.SINK

A.GND

ACL-6126 Side

External Side

Pow er

Supply

R

Load

I.OUT

A.GND

Note : For 4-20mA current sink mode, the output range should be set

as

Internal Reference with -5V and Unipolar mode.

The voltage bias of current sink mode should be within 8V ~

36V. A

12V or 24V DC power supply is the best choice for

power source.