Register Format

3.5 Emergency Shutdown Setup Register

The emergency shut down setup register allow user to enable or
disable the emergency stop function and clear EMG_SHDN sta-
tus.

The default Emg_SHDN enable value is “1”. When The bit 0 value
“1” means the function is enable and “0” menas that is disable.

When Emergency Shutdown’s Input Pin (from the terminal con-
nector) is one shot high, it will force PCI7260 enter the state of
“SHDN”( Relay Output pattern is determined on EMG_SHDN Dip
Swith(S3)). Whenever the users wants to control the relay output
by “Relay Output Control Register”, the relay pattern won’t
change until users acess the “EMG_SHDN Recovery bit”.

Address: BASE + 0x04
Attribute: Write

EMG_EN: Emergengy shutdown enable

1: emergency shutdown is enable
0: emergency shutdown is disable


Recovery: Emergency shutdown status recovery

1: EMG SHDN Status is clear
0: No effects

7

6

5

4

3

2

1

0

Recovery --- --- --- --- --- --- EMG_EN