Backplane functions, System controller slot, Star trigger slot – ADLINK PXIS-2690P User Manual

Page 16: Figure 2-8: backplane functions

Advertising
background image

8

Chassis Overview

Backplane functions

Figure 2-8: Backplane Functions

System Controller Slot

The PXIS-2690P system controller slot is at Slot 1 as defined by
PXI specifications. It has three controller expansion slots (total
four), which are used for system controller modules that are wider
than one slot. As defined in the PXI specification, these slots allow
the controller to expand towards the left to prevent the controller
from using up peripheral slots.

Star Trigger Slot

Slot 2 is reserved for the star trigger. This slot has dedicated trig-
ger lines to slots 3 to 14. The start trigger slot provides individual
triggers to peripherals and is designed for modules with ST func-
tionalities.

PXI Trigger Bus Segment and PCI Bus Segment

PXI Star Triggers

Clock 10 MHz Buffer Circuitry

System Co

ntroll

er

1

Star Trig

ger Co

ntroller

2

Peri

p

heral sl

ot

3

Peri

p

heral sl

ot

4

Peri

p

heral sl

ot

5

Peri

p

heral sl

ot

6

Local Bus

Local Bus

Local Bus

Local Bus

Peri

p

heral sl

ot

Peri

p

heral sl

ot

14

Local Bus

Local Bus

Advertising