50 hour, Drilling unit, Jt5 operator’s manual – Ditch Witch JT5 User Manual
Page 138
Advertising

JT5 Operator’s
Manual
Service - 137
50 Hour
CMW
50 Hour
Drilling Unit
Change Engine Oil and Filter (Initial)
Change engine oil after 50 hours while oil is warm
and with unit parked on level ground.
1.
Open drain (3).
2.
Replace filter (4).
3.
Close drain.
4.
Add DEO at fill (2) until oil level is at highest
line on dipstick (1).
Location
Task
Notes
DRILLING
UNIT
Change engine oil and filter
Initial service, DEO
Change drilling fluid pump oil (initial)
EO
Clean drilling fluid pump strainer
Check radiator
Change hydraulic filter
Initial service
Check rotation gearbox oil level
2 gearboxes, MPL
Inspect thrust rollers
Check battery
IMPORTANT: Use oil specified in temperature
chart found in “Recommended Lubricants/
Service Key” on page 130.
Advertising