Jt5 operator’s manual – Ditch Witch JT5 User Manual
Page 154

JT5 Operator’s Manual
Specifications - 153
CMW
Specifications are called out according to SAE recommended practices where indicated. Specifications are general and subject to
change without notice. If exact measurements are required, equipment should be weighed and measured. Due to selected options,
delivered equipment may not necessarily match that shown.
Drilling Fluid System (Onboard)
U.S.
Metric
Maximum drilling fluid flow
0-5 gpm
0-18.9 L/min
Maximum drilling fluid pressure
750 psi
51.7 bar
Fluid Capacities
U.S.
Metric
Fuel tank
13 gal
49 L
Hydraulic reservoir
8 gal
30 L
Engine oil, including filter
4.2 qt
4 L
Battery
SAE reserve capacity rating 85 min, 12V, negative ground, SAE cold crank rating @ 0°F (-18°C), 525
amps.
Noise Levels
Operator ear sound pressure level is 93 dBA sound pressure per ISO 6394
Exterior sound power level is 103 dBA per ISO 6393