Ditch Witch JT2020 User Manual
Page 120
 
JT2020 Mach 1 Operator’s Manual
Systems and Equipment - 119
Electric Strike System
CMW
Strobe light on drilling unit 
does not work during total 
test
Improper connections with 
control module
Check connections and wiring 
harness
Defective strobe light
1.
Disconnect strobe and connect to 
external 12V power source.
2.
If strobe does not work, replace it.
Defective control module
Have control module checked or 
replaced
Alarm on drilling unit does 
not work during total test
Improper connections with 
control module
Check connections and wiring 
harness
Defective alarm
1.
Disconnect strobe and connect to 
external 12V power source.
2.
If strobe does not work, replace it.
Defective control module
Have control module checked or 
replaced
Strobe light and alarm on 
drilling unit do not work 
during total test
Improper connections with 
control module
Check connections and wiring 
harness
Defective control module
Have control module checked or 
replaced
EC2 code displays and 
current problem indicator is 
on
Improper connections with 
control module
Check cable connections on control 
module and current transformer
Defective current transformer
1.
Disconnect current transformer.
2.
Check for 20-40 ohms from pin 1 
to pin 4, 20-40 ohms from pin 1 to 
pin 2, and less than 1 ohm from 
pin 2 to pin 4. 
Defective current transformer 
cable
1.
Disconnect cable from 
transformer and control module.
2.
Check continuity of cable.
3.
If continuity is zero or cable is 
damaged, replace.
Defective control module
Have control module checked or 
replaced
EV1 code displays and 
voltage problem indicator is 
on
Improper connection of voltage 
limiter to ground stake
Check voltage limiter connection to 
ground stake and verify that ground 
stake is driven into the ground
Defective voltage limiter
Have voltage limiter checked or 
replaced
Defective control module
Have control module checked or 
replaced
Problem
Possible cause
Possible solution