Esid – Ditch Witch JT2020 User Manual
Page 51
 
Controls - 50
JT2020 Mach 1 Operator’s Manual
ESID
CMW
ESID
1.
Alphanumeric display
2.
Strike indicator
3.
Alarm interrupt button
4.
Voltage problem indicator
5.
Current problem indicator
6.
OK indicator
7.
Electrical power supply indicator
8.
Self test button
Item
Description
Notes
1. Alphanumeric display
Displays amount of current 
and voltage being detected 
as a percentage of strike 
condition.
The line with the “V” shows 
voltage reading and the line 
with the “A” shows current 
reading.
2. Strike indicator
Red lights come on as values 
in display increase.
Light in triangle represents 
strike warning condition and 
will trigger alarm(s) and 
strobe(s).
IMPORTANT: System can go 
from one or two lights to an 
electric strike immediately.
If system is activated, assume a strike 
has occurred.
NOTICE: The ESID does not indicate 
proximity to electric lines. System will 
activate only when voltage and/or 
amperage detected at the drilling unit 
are above threshold minimum limits.
j07om042h.eps
1
2
3
4
5
6
7
8