2 structure of position control mode, Structure of position control mode -3 – Delta Electronics ASDA-B Series User Manual
Page 118

Chapter 6 Control Modes of Operation|ASDA-B Series
Revision January, 2009
6-3
Other
setting:
Reversed
Input pulse interface
Max. input pulse frequency
Line driver
500kpps
Open collector
200kpps
• Logic type
0=Positive Logic
1=Negative Logic
Pulse Type
Forward
Reverse
Forward
Reverse
AB phase pulse
CW + CCW pulse
Pulse + Direction
6.2.2 Structure of Position Control Mode
Basic Structure:
Position Command
Position Command
Processing
Position Control
Block Diagram
Speed
Loop
Current
Loop
Output Position
In order to pursue the goal of perfection in position control, the pulse signal should be modified through
position command processing and the structure is shown as the figure below:
INHIBIT
GNUM0
Electronic
gear ratio (1)
P1-44, P1-45
Low-pass
Filter P1-08
Pulse
Signal
Pulse type
selection
P1-00
Electronic
gear ratio (2)
P1-15, P1-45