Chapter 7 Servo Parameters|ASDA-B Series

Revision January, 2009

7-27

P1 - 03

AOUT Pulse Output Polarity Setting

Communication Addr.: 0103H

Default: 0

Related Section:

Applicable Control Mode: P/S/T

P1-46

Unit: N/A

Range: 0 ~ 1

Settings:

• Pulse Output Polarity Settings (A/B phase deviation from 90 degrees (Quadrature))

0: Forward output

1: Reverser output

P1 - 04

Reserved

Communication Addr.: 0104H

P1 - 05

Reserved

Communication Addr.: 0105H

P1 - 06

SFLT

Accel / Decel Smooth Constant of Analog Speed
Command (Low-pass Filter)

Communication Addr.: 0106H

Default: 0

Related Section:

Applicable Control Mode: S

Section 6.3.3

Unit: ms

Range: 0 ~ 1000 (0: Disabled)

P1 - 07

TFLT

Smooth Constant of Analog Torque Command
(Low-pass Filter)

Communication Addr.: 0107H

Default: 0

Related Section:

Applicable Control Mode: T

Section 6.4.3

Unit: ms

Range: 0 ~ 1000 (0: Disabled)

P1 - 08

PFLT

Smooth Constant of Position Command (Low-
pass Filter)

Communication Addr.: 0108H

Default: 0

Related Section:

Applicable Control Mode: P

Section 6.2.5

Unit: 10ms

Range: 0 ~ 1000 (0: Disabled)