Delta Electronics ASDA-B Series User Manual
Page 44

Chapter 3 Connections and Wiring|ASDA-B Series
Revision January 2009
3-19
Setting of parameter P2-10 to P2-15:
DI Code
Signal
Description
19
S-T
Speed / Torque mode switching (OFF: Speed, ON: Torque)
20
T-P
Torque / Position mode switching (OFF: Torque, ON: Position)
21
EMGS
Emergency stop (contact b)
22
CWL
Reverse inhibit limit (contact b)
23
CCWL
Forward inhibit limit (contact b)
25
TLLM
Torque limit - Reverse operation
26
TRLM
Torque limit - Forward operation
DO signal:
For example: If the users want to set DO1 to be servo ready, it only needs to set the value of parameter
P2-18 to 101 (refer to chapter 7).
NOTE
1) 0: Output function disabled
Setting of parameter P2-18 to P2-20:
DO Code
Signal
Description
01 SRDY
Servo
ready
02 SON
Servo
On
03
ZSPD
At Zero speed
04
TSPD
At Speed reached
05
TPOS
At Positioning completed
06
TQL
At Torques limit
07
ALRM
Servo alarm (Servo fault) activated
08 BRKR
Electromagnetic
brake
control
09
OLW
Output overload warning
10
WARN
Servo warning activated