Delta Electronics ASDA-B Series User Manual
Page 160

Chapter 7 Servo Parameters|ASDA-B Series
Revision January, 2009
7-7
Group 3: P3-xx
Communication Parameters
Control
Mode
Parameter
Name
Function
Default
Unit
P
S
T
P3-00
ADR
Communication Address Setting
1
N/A
{
{
{
P3-01 BRT
Transmission
Speed
3 bps
{
{
{
P3-02 PTL
Communication
Protocol
0 N/A
{
{
{
P3-03
FLT
Transmission Fault Treatment
0
N/A
{
{
{
P3-04
CWD
Communication Time Out Detection
0
sec
{
{
{
P3-05 Reserved
P3-06■
SDI
Digital Input Communication Function
0 N/A
{
{
{
P3-07
CDT
Communication Response Delay Time
0
ms
{
{
{
Explanation of symbols (marked after parameter)
(★) Read-only
register.
(▲)
Parameter cannot be set when Servo On (when the servo drive is enabled).
(●)
Parameter is effective only after the servo drive is restarted (after switching power off and on).
(■)
Parameter setting values are not retained when power is off.