MOUNTING AND INSTALLATION

0.75m min.

1

2

3

8

5

4

4

5

6

7

9

Key

1 Return circuit ¼ turn shut-off valve in the direction of the heat

pump (not included) (*)

2 Heat

pump

fl ow circuit ¼ turn shut-off valve in the direction of

the building (not included) (*)

3 Flow heat pump circuit hose in the direction of the building (not

supplied)

4 O

ring

5 Cap

6 Flow heat pump connection (Ø 1¼") to the building

7 Return connection (Ø 1¼") to the heat pump

8 Return circuit hose in the direction of the heat pump (not

supplied)

9 Insulation (not supplied)

(*) Available as an accessory

∙ Remove the protection caps (4) located on the connections.

∙ Install the fi lter on the heat pump return pipe. Install it

between 2 shut-off valves in order to be able to remove if

from the circuit and clean it periodically.

∙ Connect a fl exible pipe + the O ring and a shutoff valve to

the heat pump outlet and return connectors.

∙ Check that there are no leaks. Repair if necessary.

4.3.2

Swimming pool option

b

Caution!

Risk of damage in the case of a direct connection

to the swimming pool.

If the heat pump is connected directly to the

swimming pool, the appliance may be damaged

by corrosion.

Do not connect the heat pump hydraulic circuit

directly to a swimming pool

Use a swimming pool kit with an external heat

exchanger.

∙ In the case of an installation with a swimming pool option,

take into account the water volume up to the swimming

pool kit for proper sizing of the installation (e.g.:

expansion tanks...).

4.3.3 Condensate

discharge

i

Observe these instructions, the legal directives

and the local regulations to evacuate conden-

sates.

550

102,5

Ø25

A

B

D

C

1

2

4

3

Key

1 Condensate drain pipe

2 Adapter

3 Clip

4 Elbow

∙ Assemble the elbow and the adapter (A) and then secure it

with the clip (B).

∙ Install the condensate evacuation pipe onto the elbow.

∙ Insert the heat pump electric heater into the pipe to

prevent condensates freezing in the pipe.

∙ Insert the adapter into the hole in the base of the heat

pump (C), then turn the adapter a ¼ turn to lock it into

position (D).

∙ Connect the pipe to the condensate evacuation circuit

either in a bed of pebbles or connected to a drain using a

siphon.

∙ Make sure that the condensate does not stagnate in the

drain hose.

∙ Make sure that the drain hose is not connected tightly to

the waste water piping.