0020154078_00 - 02/13 - Glow-worm
8
APPLIANCE DESCRIPTION
3.3
Structure of the appliance
3.3.4.1 Hydraulic and refrigerant schematic
A
B
1
2
3
5
15
16
14
17
22
18
23
19
21
24
25
26
13
12
9
10
8
7
6
11
4
20
Key
1 Ventilating
fan
2 Outside air temperature sensor
3 Finned heat exchanger
4 Finned heat exchanger temperature sensor
5 4-way
valve
6 Heat pump return circuit temperature sensor
7 Expansion
vessel
8 Modulating high performance pump including a water fl ow rate
sensor
9 Water
bleed
10 Heat
pump
fl ow temperature sensor
11 Draining valve for the heat pump circuit
12 Plate to plate heat exchanger
13 Temperature sensor after plate to plate heat exchanger
14 High-pressure circuit maintenance valve
15 Refrigerant pressure switch
16 Refrigerant circuit high pressure sensor
17 Compressor discharge temperature sensor
18 Rotary
compressor
19 Filter
20 Anti-slugging
bottle
21 Electronic expansion valve
22 Compressor suction temperature sensor
23 Low-pressure circuit maintenance valve
24 Flow rate limiter in cooling mode
25 Filter
26 Gas
buff er
A Heat pump return
B Heat
pump
fl ow