Maintenance – Glow-worm Clearly Heat Pumps Envirosorb3 User Manual

Page 19

Advertising
background image

0020154078_00 - 02/13 - Glow-worm

19

MAINTENANCE

6.1

Observe maintenance intervals

∙ Maintain the product only if you are a competent person.

∙ Carry out annual maintenance.

6.2 Preparing

maintenance

6.2.1

Providing spare parts for maintenance and

repair work

∙ In case you need spare parts during maintenance or repair,

exclusively use genuine Glow Worm spare parts.

The genuine component parts of the product have been

certifi ed together with the product in the course of the

CE conformity check. If you do NOT use certifi ed genuine

Glow Worm spare parts during maintenance or repair, the

CE conformity of the product will expire. That is why we

imperatively recommend to install genuine Glow Worm spare

parts.

6.3 Pre-maintenance

instructions

Comply with the basic safety rules before performing

maintenance or installing spare parts.

∙ Shut down the system.

∙ Switch off the system electrical supply.

∙ Isolate the hydraulic circuit from the appliance using the

shut-off valves where necessary.

∙ Drain the appliance if you need to replace hydraulic circuit

components.

∙ Protect all electric components from water if you have to

work on the appliance.

6.4 Annual

Maintenance

∙ Check the proper functioning of safety devices.

∙ Check the pressure of the water system.

∙ Check tightness of refrigerant circuit.

∙ Check that there are no traces of rust or oil around the

refrigerant circuit’s components.

∙ Ensure that the appliance’s components are neither worn

nor broken.

∙ Check that the wires are fi rmly attached to the electrical

terminals.

∙ Check the appliance’s grounding.

∙ Check the fl ow temperature of the heat pump and the

setting points.

∙ Check that the fan rotates freely.

∙ Check the pressure of the expansion vessel.

6.5 Cleaning

6.5.1 External

cleaning

∙ If the appliance needs cleaning, refer to the user manual.

6.5.2

Cleaning the components

∙ Check the absence of ice on the compressor.

∙ Remove any dust from electronic boxes.

∙ Clean the air / refrigerant battery and make sure that air

circulates between the fi ns and around the unit.

∙ Check that condensates can properly drain from the heat

pump by removing the adapter located under the heat

pump (turn it a ¼ turn to unlock).

∙ Clean the evaporator on both sides using a brush with soft

bristles. Remove the fan blades and the rear grill before

cleaning.

a

Warning!

Risk of minor injury.

Handling the fan blades and grill can cause cuts.

Wear protective gloves to perform this

operation.

6.6

Draining

∙ Cut off the appliance’s electricity supply.

2

1

14mm

Key

1 Hydraulic circuit venting valve

2 Draining

hose

∙ Close the shut-off valves located behind the heat pump.

∙ Engage a hose (2) to the venting valve (1) or place a

container under the venting valve (1) to drain the hydraulic

circuit.

∙ Open the bleed valve (1) with a fl at spanner.

Note: if necessary, the heating installation can be drained via

this bleed valve by opening the shutoff valves located at the

rear of the heat pump.