Appendix – Glow-worm Clearly Heat Pumps Envirosorb3 User Manual

Page 25

Advertising
background image

0020154078_00 - 02/13 - Glow-worm

25

APPENDIX

Fault

codes Description

Possible cause

514

The compressor inlet

temperature sensor or

connection is out.

The sensor is defective or is not

correctly connected to the main

PCB.

517

The compressor outlet

temperature sensor or

connection is out.

519

The heating return

temperature sensor or

connection is out.

520

The fl ow heating

temperature sensor or

connection is out.

526 Coil sensor interrupt or

short circuit.

532

The fl ow on heat pump

water circuit is too low

or too high (see section

5.4.2).

Water pump defective.
There is a lack of water.
Anti-silt fi lter missing or clogged

in the brine water circuit’s

backfl ow.
The circuit was not properly bled.
The pressure drop is too high in

the hydraulic circuit.

536

The compressor

discharge temperature

is too high (depends

on the compressor

operating zone).

The compressor safety thermostat

is tripped.
The pressure switch or its

electrical connection is defective.
The refrigerant fl uid level is low
The sensor is defective or is not

correctly connected to the main

PCB.
Pre-expansion in the liquid line

(load loss)
The electronic expansion valve is

defective.
The plate exchanger is clogged.

755 Position of 4-way valve

error.

There is a mechanical or electrical

problem. Force the 4-way valve

from the control box. While

forcing, check that the coil voltage

is correct.

537

The discharge pressure

on compressor is too

high.

Blocking fault after 3rd

trigger attempt

There is an excess or a lack of

refrigerant.
Vacuum insuffi cient
Presence of incondensables in the

circuit
The pressure switch or its

electrical connection is defective.

537

The discharge pressure

on compressor is too

high.

Blocking fault after 3rd

trigger attempt

Pre-expansion in the liquid line

(load loss)
Poor water fl ow rate.
The water fl ow sensor is defective.
Insuffi cient heat exchange at the

plate to plate exchanger.

539

The pressure of the

low pressure circuit is

too low.

Lack of refrigerant.
Lack of airfl ow.
There is no defrosting.
The condensate tray resistance

heater is faulty.
The 4-way valve is defective.
The electronic expansion

valve’s motor is defective or the

connection is defective.

546 Cooling circuit pressure

sensor fault.

The sensor is defective or not

correctly connected to the main

circuit board.

Fault

codes Description

Possible cause

554 Operation outside the

compressor's limit.

An excess or a lack of refrigerant.
Presence of incondensables.
The electronic expansion valve is

defective.
Pre-expansion in the liquid line

(load loss)
Insuffi cient heat exchange at the

plate to plate exchanger or tube

exchanger.
The 4-way valve is defective.

582

The expansion valve

motor or connection

is out.

The wiring harness is damaged or

disconnected.

585

The subcooling

temperature sensor

in heating mode or

connection is out.

The sensor is defective or is not

correctly plugged in to the main

PCB.

685 eBus communication

with heat pump is out.

The appliance is not connected to

the control box.
The cable polarity is reversed.

750 Compressor

disconnected.

The wiring harness is damaged or

disconnected.

751 Compressor

overcurrent.

Compressor fault.
The heat pump supply voltage is

too low.
The fi nned heat exchanger is

dirty.
The plate heat exchanger is dirty.

752 Inverter driver error.

The inverter box is damaged.
The inverter box radiator is

blocked.
The supply voltage is incorrect.

753 Communications error

with the inverter box.

The connection between the main

circuit board and the inverter box

is damaged or disconnected.
The inverter box is not powered

up.

754 Fan coil board internal

error (FMU).

The fan is defective.
The connection between the main

circuit board and the fan card is

damaged or disconnected.
The fan card is defective.
The fan card power supply is

defective.

774

The air inlet

temperature sensor or

connection is out.

The sensor is defective or not

correctly connected to the main

circuit board.

For further technical information please

call 0844 736 1143