MOUNTING AND INSTALLATION

Envirosorb3 8

Envirosorb3 11

Recommended cable size

eBus

2 x 0.75 mm²

2 x 0.75 mm²

Recommended cable size

eBUS + FLOOR H

4 x 0.75 mm²

4 x 0.75 mm²

∙ Pass the cables through the heat pump cable gland (see

section 4.4.3).

∙ Connect the e-BUS cable to the system control box

complying with the polarity ±.

∙ If a manual reset floor heating protection device (55°C)

is installed on the heating circuit outlet, remove the link

from the terminal (2) and then connect the floor heating

protection device to this terminal.

4.4.3

Cable

routing

b

Caution!

Risk of appliance malfunction

If the very low voltage and low voltage cables are

in the same duct, the very low voltage signal will

be disturbed by the low voltage.

Run the very low voltage and low voltage

cables in different ducts.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

A

B

C

D

ØA

ØA

eBus

230V

Key

eBUS

e-BUS cable and fl oor heating protection device cable

gland

230V

230V supply cable gland

∙ Measure the diameter of the cable (A).

∙ Use a drill of the same diameter as the cable and drill

through the cable gland seal (B).

∙ Pass the cable through the cable gland provided for this

purpose (C)

∙ Set the cable gland with 2 fl at spanners (D) to get it tight.