Technical data, 10 technical data, 3 refrigerant fl uid – Glow-worm Clearly Heat Pumps Envirosorb3 User Manual

Page 22

Advertising
background image

0020154078_00 - 02/13 - Glow-worm

22

TECHNICAL DATA

9.3 Refrigerant

fl uid

b

Attention!

Risk of pollution!

This appliance contains R410-A refrigerant fluid

which must never be released to the atmosphere.

R410-A is a fluoride greenhouse gas covered by

the Kyoto protocol.

Before discarding the appliance, correctly

recover the refrigerant fl uid into an appropriate

container to be recycled in compliance with the

regulations in force.

The recycling of the refrigerant fl uid must be performed by the

qualifi ed professional who installed the device.

The personnel approved for this recuperation must have an

appropriate certifi cation according to the regulations in force.

10

Technical data

i

This technical data is valid for a new appliance

with its own heat exchangers.

Description

Unit

Envirosorb3 8

Envirosorb3 11-1ph

Min. operating air temperature (heating and tank heating)

°C

-20

-20

Max. operating air temperature (heating)

°C

35

35

Max. operating air temperature (domestic hot water)

°C

46

46

Specifi cations, with radiators
(start : 45°C, return : 40°C, dry temperature (wet) 7 (6)°C)

Heating output

kW

7,20

10,20

COP* A7(6) W45-40

3,5

3,35

(start : 55°C, return: 47°C, dry temperature (wet) : 7 (6)°C)

Heating output

kW

6,60

9,40

COP* A7(6) W55-47

2,70

2.60

Specifi cations, with underfl oor heating
(start : 35°C, return : 30°C, dry temperature (wet) : 7 (6)°C)

Heating output

kW

7,60

10,60

COP* A7(6) W35-30

4,50

4,30

(start : 35°C, return : 30°C, dry temperature (wet) 2 (1)°C)

Heating output

kW

5,60

8,40

COP* A2(1) W35-30

3,40

3,10

Refrigerant circuit
Type of refrigerant

R-410A

Quantity of refrigerant

kg

1.950

3.530

Type of compressor

Rotary

Type of oil

specifi c Polyvinylether (PVE) oil.

Type of regulator

Electronic

Maximum relative operating pressure (PS)

bar

41.5

41.5

Pa

41.5 x 10

5

41.5 x 10

5

Heat pump circuit

Min. fi lling pressure.

bar

1

1

Pa

1 x 10

5

1 x 10

5