3 appliance description – Glow-worm Clearly Heat Pumps Envirosorb3 User Manual

Page 6

Advertising
background image

0020154078_00 - 02/13 - Glow-worm

6

NOTES ON THE DOCUMENTATION

2 Notes on the documentation

∙ These instructions consist of, Installation, Servicing, Fault

Finding and Replacement of Parts. The instructions are an

integral part of the appliance and must be handed to the

user on completion of the installation.

2.1

Observe other applicable documents

∙ Observe absolutely all operating and installation

instructions enclosed with the product, for the various

parts and components of the system.

2.2 Storing

documents

∙ Pass these instructions and all other applicable documents

to the system user.

The system user should retain these instructions so that they

are available when required.

2.3

Validity of the instructions

These instructions apply exclusively to:

Type overview

Product

Type designation

Article number

Envirosorb3 8

0010011967

Envirosorb3 11

0010011968

For all system schematics and information please refer to the

heatpump system manual.

3 Appliance

description

3.1 Safety

devices

- The appliance is designed to operate with an outside

temperature between -20°C and 35°C in heating mode and

between -20°C and 46°C for tank heating.

- A high pressure switch limits the operation of the

appliance when the refrigerant fl uid pressure exceeds

41.5 bar (gauge pressure) (41.5 x 10

5

Pa) (relative pressure).

- When the appliance is shut down, the compressor

crankcase heater is activated below 7°C at the compressor

outlet to prevent any damage when restarting.

- If the compressor outlet temperature is below 1°C, the

appliance will not allow the compressor to start.

- A temperature sensor at the compressor outlet limits

the operation of the heat pump when the temperature

measured by this sensor is higher than the maximum

limit. This value varies depending on the evaporation and

condensation temperatures.

- The appliance is equipped with a measuring device that

checks the water fl ow rate at start-up.

- An anti-freezing protection device runs the heat pump

hydraulic pump when the hydraulic circuit temperature is

lower than 3°C. However, it is necessary to add anti-freeze

to the heat pump hydraulic circuit. Without the addition

of outside energy or in the case of a power cut, the circuit

water can drop below the freezing point.

3.2

Concept of operation

A heat pump (HP) is a thermodynamic machine which

transfers heat from one location to another. To do so, it

employs the characteristics of a refrigerant fl uid.

The system is composed of the following circuits:

- The refrigerant circuit which transfers heat to the

water circuit following the evaporation, compression,

condensation and expansion of the fl uid.

- The heating circuit.

3.2.1 Heating

mode

1

2

3

4

5

6

Key

1 Fin

exchanger

2 Four

way

valve

3 Ventilating

fan

4 Compressor

5 Expansion

valve

6 Plate to plate heat exchanger

3.2.2 Defrosting

mode

1

2

3

4

5

6

Key

1 Fin

exchanger

2 Four

way

valve

3 Ventilating

fan

4 Compressor

Advertising