3 Ducting, Controls and Condensate

3.1 Ducting connections

Refer to diagram 3.3.

• Atmosorb HRD 275: 4 x air duct connections ø 150 mm, or

alternative ø 160 mm and ø 180 mm

• Atmosorb HRD 350: 4 x air duct connections ø 180 mm, or

alternative ø 200 mm

3.2 Bypass(Optional)

Refer to diagram 3.2.

• Atmosorb HRD 275 and HRD 350: 4 x air duct connections

ø 150 mm, or alternative ø 160 mm and ø 180 mm.

1 Outside air

2 Exhaust air (from living room)

3 Fresh air (to living room)

4 Outgoing air (to outside)

FILTER

Diagram 3.2

VENTILATION FLAP

AIR INLET FROM

OUTSIDE

14881

1

4

2

3

Diagram 3.3

14878

Diagram 3.1

14879

3.3 Remote Control

• Control cable from the remote control to the unit is a 2-core

cable, with cross-section 0,75 mm

2

. Maximum cable length

300m.

The connection must comply with the current rules and

regulations.

3.4 Condensate Drain Trap

The condensate drain trap must be connected to the threaded

tube under the unit. Additionally, an odour trap is required in

the waste water system. For hygienic reasons, between the

drain traps an air gap of at least 20 mm must be provided.

• Condensed water drain G 3/4 connection for the condensate

drain trap.

• The attached condensed water drain trap is designed to

compensate pressure between the device and the installation

room, for that reason it must always be filled with clear water.

EXTERNAL AIR OUTLET

FRESH AIR OUTLET

(TO ROOM)

FAN

CIRCUIT BOARD

FAN EXHAUST
CONDENSATE DRAIN

OUTLET
3 STAGE SWITCH

CONNECTION

BYPASS CONNECTION

EXTERNAL AIR INLET

AIR EXHAUST

EXHAUST AIR FILTER

HEAT EXCHANGER

EXTERNAL AIR FILTER