4 Installation

4.4 Air Duct Connections

Before executing the final connection check the air ducts are

still clean. If necessary, clean the air ducts.

Only then connect the air ducts to the unit.

Connect the air ducts to the connections on top of the unit.

NOTE: Air ducts must be tightly connected to the unit - use

suitable accessories or sealing material. Insulation of the

fresh air and outgoing air ducts must be diffusion resistant.

4.5 Opening and Closing the Unit

The unit is equipped with a fixed front panel. For mounting

and maintenance work on the unit it is necessary to remove

the front panel.

IMPORTANT: Switch off the mains supply to the unit before

starting to work.

Remove the filters from the Atmosorb first, to enable removal

of the front panel.

Pull both filters out of the unit, see diagram 4.4

Remove the screw from the LH toggle-type fastener below the

unit.

Then open both toggle-type fasteners.

Pull the lower part of the front panel towards you.

Now lift the front panel above the top fixing points.

To close the unit, carry out the steps in reverse order.

IMPORTANT: Always ensure the screw is replaced into the

left hand toggle after re-assembly to avoid unauthorised

access to the unit.

a

a

c

b

e

d

Diagram 4.4