Introduction – Glow-worm Clearly Hybrid - Universal Module System User Manual

Page 17

Advertising
background image

0020096317_01 - 02/11 - Glow-worm

- 15 -

Key

1 2 port valve "heating zone 1"

2 Heating circuit zone 1

3 Climapro2 RF programmable wireless room thermostat "zone 1"

4 2 port valve "heating zone 2"

5 Heating circuit zone 2

6 Climapro2 RF programmable wireless room thermostat "zone 2"

7 2 port valve "heating zone 3"

8 Climapro2 RF programmable wireless room thermostat "zone 3"

9 Heating circuit zone 3

10 Systempro control unit

A Heating circuit return

B Heating

circuit

fl ow

Application conditions

- The Systempro control unit manages up to 3 heating zones.

- Each wireless room thermostat can control a heating zone.

- Zones must be same temperatures.

- The installation can be performed with a low-temperature

underfl oor heating (heating outlet temperature < 50°C) or low

temperature radiators (heating outlet temperature < 70°C).

e

Use 0.75 mm² section cables for the electrical

connections to the control unit.

Control unit settings

Description of main settings

Setting

Did you install a multizone kit ?

Yes

Max. heating fl ow temperature for the low

temperature zone

T < 30°C

Max. heating fl ow temperature for the high

temperature zone

T < 70°C

2 port valve electrical connections

- When the 2 port valve is connected to REL3:

Connect the neutral wire (blue) of the valve to the “N” of the

REL3 connector.

Connect the live wire (brown) of the valve to the “L” of the REL3

connector.

Connect the earth wire (yellow/green) of the valve to the earth

of the REL3 connector.

Electrically insulate the red and grey wires of the valve as they

are not used.

- When the 2 port valve is connected to REL4 or 5:

Connect the neutral wire (blue) of the valve to the “N” and

the live wire (brown) of the valve to the “L” of the REL4 or 5

connector.

Connect the earth wire (yellow/green) of the valve to the earth

of the REL3 connector.

Electrically insulate the red and grey wires of the valve as they

are not used.

INTRODUCTION

EN