0020096317_01 - 02/11 - Glow-worm

- 17 -

Key

1 Systempro control unit

2 Domestic hot water cylinder

2.1 Domestic hot water NTC

2.2 Domestic hot water thermostat

3 Boiler

4 Non-return valve (recommended to prevent burner ignition triggered

by thermo-siphoning)

5 Domestic hot water cylinder 2 port valve

6 Boiler circuit 2 port valve

A Heating circuit return

B Heating

circuit

fl ow

C Cold water supply

D Domestic hot water fl ow

E Boiler

circuit

fl ow

F

Boiler circuit return

G Heat pump circuit fl ow

H Heat pump circuit return

I

Heat pump circuit safety valve discharge

Application conditions

- The Systempro control unit manages the Domestic Hot Water

cylinder (only with diagram no 10).

- The maximum working pressure of the domestic hot water

circuit is 10 bar. If the cold water supply pressure exceeds this,

then a pressure-reducing valve must be fi tted in the supply to

the boiler.

- In areas where the water is ‘hard’ (i.e. more than 200 mg/L

of calcium carbonate), it is recommended that the hot water

setting is reduced and that a scale reducer is fi tted, refer to the

manufacturer’s instructions or consult the local water company

for additional advice.

e

Use 0.75 mm² section cables for the electrical

connections to the control unit.

Control unit settings

Description of main settings

Setting

Installation option: Domestic Hot Water cylinder

On

The type of tank

NTC sensor (1NTC)

or

Thermostat (1Therm)

INTRODUCTION