5 Assembly and installation

18

Installation instructions Envirosorb₃ 0020154078_03

5.4.3

Laying the 24 V cabling

X4

X9

EBUS

X7 FLOOR H

3

1

2

1 eBUS connection in the

heat pump (observe the
polarity)

2 Limit thermostat connec-

tion (underfloor protective
circuit)

3 eBUS connection in the

heat pump control module

1.

Feed the cable through the cable duct.

Envirosorb

3

5

Envirosorb

3

8

Envirosorb

3

11

Envirosorb

3

15

Recommended eBUS cable dimen-
sion

2 x 0.75 mm²

Recommended cable dimension for
eBUS + limit thermostat

4 x 0.75 mm²

2.

Connect the eBUS cable to the system controller.

3.

If you install a limit thermostat (e.g. 50 °C) in the heat-
ing circuit flow, remove the bridge from terminal (2) and
connect the limit thermostat to this terminal.

5.4.4

Installing the cable duct

Caution.
Risk of malfunction due to incorrect rout-

ing of the supply lines.
If you route the supply lines for the power

supply and the eBUS line through the same

cable duct, the signal will be disrupted.

Route the supply lines for the power sup-

ply and the eBUS line through various

cable ducts in the product.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

1

2

3

4

ØA

ØA

1

2

1 eBUS line and limit ther-

mostat line cable duct

2 Power supply cable duct

1.

Measure the diameter of the cable.

2.

Drill a hole the same size as the cable diameter in the
cable duct.

3.

Route the cable through the cable duct.

4.

Tighten the cable duct with two open-end spanners.