Code Meaning

72

Fault: Inverter overcurrent

73

Fault: Inverter voltage too low

74

Fault: Inverter voltage too high

75

Internal inverter fault message

76

Fault: Inverter heat sensor

77

Fault: Inverter overload

78

Fault: Fan Management Unit PCB

79

eBUS communication error

80

Fault: Flow rate

81

Communication error with inverter

82

Fault: Maximum compressor current

84

Fault: Electronic expansion valve

85

Fan speed too low

88

Coding resistance fault

89

Fault: Underfloor protective circuit

90

Fault: 4-way valve

99

Fault with the product: Take note of the fault codes.

E

Overview of fault codes

Code

Meaning

Cause

37

The fan speed is too low.

Obstruction in the product's air guiding

Fan motor not connected or faulty

Power supply to the fan PCB is faulty

42

Fault: Coding resistance

The product's coding resistance is missing or is faulty

Coding resistance value outside the permissible range

86

Safety thermostat for the underfloor heating triggered

Underfloor heating temperature too high

Heating circuit flow rate too low

Underfloor heating circuit is closed

103

Fault: Spare part detection

The main PCB that is fitted as a spare part or the inverter does
not match the product

514

Sensor fault: Comp. inlet temp.

Sensor is faulty or incorrectly connected to the main PCB

517

Sensor fault: Comp. outlet temp.

519

Sensor fault: Return temperature

520

Sensor fault: Flow temperature

526

Sensor fault: Heat exchanger temp.

Sensor is faulty or incorrectly connected to the main PCB

532

Building circuit: Flow rate too low

Pump faulty
Check the specific flow rate in forced mode

Between 7000 and 7700 l/h: Alarm

Between 7700 and 8200 l/h: The pump runs dry (no water in
the heating circuit; the heating circuit loses water)

Between 8200 and 8700 l/h: Fault in the electronics

Between 8700 and 9200 l/h: Pump blocked

Between 9200 and 10,000 l/h: No PWM signal (cable faulty
or not connected; fault in the main PCB)

Pump cabling has not been carried out correctly (PWM and sup-
ply)

Low water pressure

Dirt filter in the heating circuit return is missing or blocked

Heating circuit not fully purged

Pressure loss in the heating circuit too high