4 overview of the equipment, 1 type designation and serial number, 2 information on the identification plate – Glow-worm Envirosorb3 User Manual

Page 9: Overview of the equipment 4, 4overview of the equipment

Advertising
background image

Overview of the equipment 4

0020154078_03 Envirosorb₃ Installation instructions

9

3.5

System diagram (Envirosorb

3

8,

Envirosorb

3

11, Envirosorb

3

15)

e

1

3

12

16

17

19

25

23

15

21

14

11

4

24 20

2

22

5 13

8

9

6
7

10

A

B

18

1 Fan

2 Air inlet temperature

sensor

3 Ribbed pipe heat ex-

changer

4 Temperature sensor of

the ribbed pipe heat ex-
changer

5 4-way valve

6 Return heating circuit

temperature sensor

7 High-efficiency pump with

flow sensor

8 Purging valve

9 Flow heating circuit tem-

perature sensor

10 Drain valve

11 Plate heat exchanger

12 Temperature sensor after

the plate heat exchanger

13 Service valve for the high-

pressure range of the
coolant circuit

14 High-pressure pressure

switch in the coolant cir-
cuit

15 High-pressure sensor in

the coolant circuit

16 Compressor outlet temper-

ature sensor

17 Rotary piston compressor

18 Filter

19 Liquid separator

20 Electronic expansion valve

21 Compressor inlet temper-

ature sensor

22 Service valve for the low-

pressure range of the
coolant circuit

23 Flow rate limiter (cooling

mode) on Genia Air 8/1
only

24 Filter

25 Gas buffer

A Heating return

B Heating flow

4

Overview of the equipment

4.1

Type designation and serial number

1

1

The type designation and serial number are on the identifica-
tion plate (1).

4.2

Information on the identification plate

Information on the identi-
fication plate

Meaning

Serial no.

Unique unit identification number

P max

Maximum rated power

I

Max. operating current

I max

Maximum start-up current

R410A

Coolant type and fill quantity

PS

R

_LP

PS

R

_HP

Min. and max. operating pres-
sure in the coolant circuit

PS

H

min

PS

H

max

Minimum and maximum operat-
ing pressure in the heating circuit

COP (Ax/Wxx)

Output figure (coefficient of
performance) at an air inlet
temperature of xx °C and a
heating flow temperature of
xx °C

(Ax/Wxx)

Heating output at an air inlet
temperature of xx °C and a
heating flow temperature of
xx °C

Volt

Compressor, pump and control-
ler mains voltage

Hz

Power frequency

IP

Protection class

Advertising