Installation, 7 appliance installation, 1 scope of delivery – Glow-worm Ultracom2 sxi User Manual

Page 12: 2 recommendations before installing

Advertising
background image

0020092785_02 - 05/10 - Glow-worm

- 10 -

7 Appliance installation

7.1

Scope of delivery

The appliance is delivered in a single carton with a document

pack and fittings.

i

The flues package will be ordered according to the

configuration of the installation.

• Please check the contents.

1

4.7

2.1

2

2.2

2.3

2.4

2.5

3

4

4.1

4.2

4.3

4.4

4.5

4.6

Key

1

boiler

(x1)

2

Accessories bag

(x1)

2.1

Pressure relief valve connecting pipe

(x1)

2.2

Connection bag

(x1)

- Heating return valve

(x1)

- Heating flow valve

(x1)

- Gas isolation valve

(x1)

2.3

Hanging bracket

(x1)

2.5

Seals bag

(x1)

- flat seal ½"

(x1)

- flat seal ¾"

(x5)

2.6

Compression fitting

(x1)

3

Wall template

(x1)

4

Documents bag

(x1)

4.1

Installation and servicing manual

(x1)

4.2

flue book

(x1)

4.3

Instructions for use

(x1)

4.4

Extended guarantee leaflet

(x1)

4.5

Guarantee envelope pack

(x1)

4.6

Magnetic lighting instruction label

(x1)

4.7

Gas conversion label

(x1)

7.2

Recommendations before installing

7.2.1

Heating circuit design

3

2

1

4

5

6

7

Key

1 Drain point

2 External bypass (if required)

3 boiler

4 Additional expansion vessel (if required)

5 Heating return circuit

6 Heating flow circuit

General

This boiler is designed to provide central heating from a sealed

water system with a fully indirect cylinder. The pump, expansion

vessel and associated safety devices are all fitted within the

boiler.

Safety valve

The safety valve is an integral part of the boiler and it cannot

be adjusted. The pipe from the safety discharge valve must

discharge safely in accordance with standards.

Expansion vessel

The boiler has an integral expansion vessel with a capacity of 8

litres (1.76 gallons), with a charge pressure of 0.75bar.

i

The heating system volume should be calculated to

ensure that the expansion vessel is suitable, it may

be necessary to add an additional vessel.

- In GB, Guidance on vessel sizing is also given in the current

issue of BS5449 and BS7074 Part 1.

- In IE, current edition of I.S.813 “Domestic Gas Installations”.