0020092785_02 - 05/10 - Glow-worm

- 5 -

2.5

Hydraulic schematic

8

7

6

5

4

3

2

1

9

10

11

12

13

14

17

16

15

18

Key

1 Heating safety valve

2 by-pass

3 Heating return thermistor

4 Condensate trap

5 Ignition and control electrode

6 burner

7 Main heat exchanger

8 Thermal fuse

9 flue outlet

10 Silencer

11 Heating expansion vessel

12 fan

13 Gas control valve

14 Ignition module

15 Heating flow thermistor

16 Air vent

17 Pump

18 filling taps

A Heating flow

b Pipe for heating safety valve

C Gas

D Heating return

G Condensate drain