4 Domestic Hot Water System Design

• Copper tubing or plastic hep

2

o may be used for the domestic

hot water system. Unnecessary pressure losses should be
avoided.

• A flow restrictor limiting the flow through the boiler to a
maximum of 12 l/min is fitted to the boiler.

• The boiler will operate with a minimum supply pressure of 0,7

bar, but under reduced flow rate. Best operating comfort will be
obtained from a supply pressure of 1 bar.

'Hard Water Areas'

In areas where the water is 'hard', more than 200mg/litre, it is
recommended that a proprietary scale reducer is fitted in the
cold water supply to the boiler.

1 - Domestic thermistor
2 - Three way valve
3 - Gas valve
4 - Ignition module
5 - Heating element
6 - Micro accumulation vessel
7 - Burner
8 - Ignition electrode
9 - Combustion chamber
10 - Micro accumulation vessel thermistor
11 - Main heat exchanger
12 - Air pressure switch
13 - Heating safety valve (3 bar)
14 - Electronic control (PCB)
15 - Domestic water flow sensor
16 - Bypass
17 - Domestic heat exchanger
18 - Pump
19 - Expansion vessel
20 - Heating thermistor
21 - Overheat safety thermostat
22 - Flame sense electrode
23 - Fan
24 - Domestic safety valve (10 bar)
25 - Loss of water sensor
A - Heating return
B - Cold water inlet
C - Heating flow
D - Domestic hot water outlet
E - Gas

10026

5 Boiler Schematic