16 routine cleaning and inspection – Glow-worm Xtrafast 96-120 User Manual

Page 24

Advertising
background image

24

2000221595

16 Routine Cleaning and Inspection

16.8 Burner, refer to diagram 16.4.

• Undo main gas supply nut from under the sealed chamber.

Note: The washer between main burner and main burner gas
supply must be kept for use on reassembly.

• Pull off ignition leads from gas control valve.

• Slacken but do not remove, two burner support screws at rear
of burner chamber using a long blade screw driver.

• Ease burner from boiler by lifting up from key hole slots,
threading the gas supply and ignition leads through the grommets
and pulling forwards, (taking care not to damage the insulation).
Before you completly remove the burner pull off flame sense
lead from flame sense electrode.

• Clean burner by washing in soapy water. Dry thoroughly
before refitting.

• When refitting burner ensure that the burner locates and seals
correctly through the grommets.

Note: To gain access to injectors for removal, refer to Section,
19.24 in Replacement of Parts
.

9663

Diagram 16.4

9661

9667

MAIN GAS
SUPPLY NUT

GROMMETS

BURNER
SECURING
SCREWS

FLAME SENSE
ELECTRODE

IGNITION
LEADS

9344

16.9 Heat exchanger, refer to diagram 16.5.

• Disconnect electrical leads from fan.

• Unscrew and remove two fan retaining screws from the right
hand side edge of fan mounting plate.

• Remove fan with mounting plate attached by pulling forward
and out of boiler.

• Remove air pressure switch sensing tube from sensing probe
on flue hood.

• Remove screws securing flue hood to rear panel

• Lift flue hood clear of heat exchanger and examine for debris.

• Using a soft brush or vacuum clean as required.

DO NOT USE ANY TOOL LIKELY TO DAMAGE PAINTED
FINISH OF HEAT EXCHANGER.

Note: When re-fitting fan, make sure that the two lugs on the fan
mounting plate engage in the flue hood

9670

Diagram 16.5

9660

9665

FAN RETAINING SLOTS

9662

9664

IGNITION
ELECTRODE
ASSEMBLY

Advertising